Starting from:

$29

Chinese Standard: YY/T 1607-2018

This standard is the Chinese version electronic standard. After you successfully purchase, we will send the electronic version of this standard to your email address. If you have any question, please contact email: ChineseStandardsLibraryS001@gmail.com.


Radiation sterilization of medical device—Method of dose setting


Standard in brief
Scope of Application:  
本标准规定了GB 18280.2-2015中方法2A和2B的一种改进方法,能够减少确定最小剂量的增量剂量的组数,该最小剂量可以达到预期无菌保证水平。本标准适用于生物负载低或处于低辐射抗力,且证明与历史水平一致时的产品。不适用于生物负载未被评估的产品。

Basic information
Standard No:YY/T 1607-2018
Standard Name:医疗器械辐射灭菌 剂量设定的方法
English Name:Radiation sterilization of medical device—Method of dose setting
Standard Status:现行
Release Date:2018-06-26
Effective Date:2019-07-01
Language of Publication:中文简体

Standard Classification
ICS Number:11.080.01
CCS Number:C47

Related Standards
Referenced Standards:GB 18280.2-2015,GB/T 18280.3-2015

Publication Information
Number of pages:24
Number of words:36 K
Format:大16
Edition:1
Color Pages:0
Electronic Version:Yes
Color Images:No
Print Publication Date:2018-07-01

Standard Revision Information
Has Amendment:No

Other Information
Application Dept:国家药品监督管理局
Standard Type:QT
Standard Attribute:YY
Other Standard Number:1607
Drafter:陈强、黄德球、刘智伟、章定严、黄鸿新、刘江平、徐海英、李伟明、方娟玲、高扬
Drafting Organization:上海金鹏源辐照技术有限公司、上海辐新辐照技术有限公司、广东省医疗器械质量监督检验所
Management Organization:全国消毒技术与设备标准化技术委员会(SAC/TC 200)
Proposing Department:国家药品监督管理局